Ventilation double flux

HR Mural

  • HR Mural 450

    HRMural is a range of controlled mechanical ventilation units with high efficiency heat recovery (up to 96%)

  • HR Mural 600

    HRMural is a range of controlled mechanical ventilation units with high efficiency heat recovery (up to 96%)

  • HR Mural 1200

    HRMural is a range of controlled mechanical ventilation units with high efficiency heat recovery (up to 96%)

  • HR Mural up 300&400eco

    Build in a compact Polypropylene casing this high efficiency heat recovery unit fits perfectly in multidwelling houses and holiday cottages.

(English) Mural is a range of controlled mechanical ventilation units with high efficiency heat recovery (up to 96%), composed of a counter flow aluminium plate exchanger, galvanized steel, class G4 and F7 (option) filters, a 70% bypass (100% for the HR Mural up 300 & 400eco) and centrifugal fans with high efficiency electronic motor (TAC series), from which it draws all the advantages.
The efficiency of the exchanger often makes adding a post- heating (or post-cooling) system superfluous, although such a system

is provided as an option. It is delivered ready to use, entirely pre-wired -- the options too -- and with a remote control (to choose) or a MODBUS/ KNX communication for controlling the device without opening it... just connect to the power supply (outside the unit) and to the remote control or the MODBUS/KNX communication and to activate the unit, and it’s ready to run. The 450 model is available with horizontal or vertical (up version) airflow directions. Backward fans are mounted in the 300-400 and 450 ECO models.


Downloads

  Category Download
  Category Download
Quick commercial brochure – REC unit
  1 files      4452 downloads
Brochures Download
  Category Download
Catalogue – HR Mural Up 300 & 400 Eco
  2 files      397 downloads
Catalogues Download
Catalogue – HR Mural
  1 files      663 downloads
Catalogues Download
  Category Download
(English) Drawings DWG for product range MURAL PX (FW)
  10 files      41 downloads
Documentation technique Download
(English) Sensors – Pressure – Temperature – Humidity
  3 files      225 downloads
Documentation technique Download
(English) User Manual TAC5 ADVANCED SETUP – HRmural
  1 files      351 downloads
Documentation technique Download
(English) Installation Manual TAC5 controls – HRmural
  1 files      384 downloads
Documentation technique Download
(English) Installation Manual – HRmural UP ECO
  6 files      217 downloads
Documentation technique Download
(English) Installation Manual – HRmural
  1 files      418 downloads
Documentation technique Download
(English) User Manual TAC5 controls + accessories – HR units
  6 files      563 downloads
Documentation technique Download
(English) Installation Manual 3way valve on TAC5 – HR units
  1 files      166 downloads
Documentation technique Download
(English) Installation Manual TAC5 SAT circuits – HR units
  6 files      270 downloads
Documentation technique Download
(English) Installation Manual TAC5 sensors – HR units
  5 files      183 downloads
Documentation technique Download
(English) Installation Manual TAC5 interfaces – HR units
  4 files      305 downloads
Documentation technique Download
  Category Download
TACtouch Software update
  16 files      298 downloads
Programmes Selections Locked
(English) SAT ETHERNET – IP CONFIGURATOR
  1 files      218 downloads
Programmes Selections Locked
(English) Selection Software
  2 files      242 downloads
Programmes Selections Locked
KNX START-UP project
  8 files      221 downloads
Programmes Selections Locked
  Category Download
(English) DS140/DS160 replacement kit
  15 files      14 downloads
Sources, Info additionnelles Download
(English) Passive House certificate – MURAL P400T
  1 files      49 downloads
Certificats Download
(English) Passive House certificate – MURAL P300T
  1 files      49 downloads
Certificats Download
(English) VDI 6022 certificate – HRmural
  1 files      40 downloads
Certificats Download
(English) Ecodesign Datasheets – HRmural
  9 files      58 downloads
Certificats Download
Drawings – HR Mural
  12 files      83 downloads
Info additionnelles Download
(English) EC Declaration of compliance – TAC fans
  1 files      66 downloads
Certificats, Info additionnelles Download
(English) CC RoHS TAC EON – TAC fans
  1 files      116 downloads
Certificats, Info additionnelles Download
(English) CC Amca Ahsrae – Lemmens products
  1 files      137 downloads
Certificats, Info additionnelles Download
Filter kit list
  2 files      280 downloads
Info additionnelles Download
(English) Warranty certificate – Lemmens products
  1 files      130 downloads
Certificats, Info additionnelles Download
Picture – HR Mural
  7 files      41 downloads
Images Download
Specifications – HR Mural
  1 files      63 downloads
Descriptifs pour cahiers des charges Download
CE Déclaration de conformité – REC
  2 files      69 downloads
Certificats Download
Règlement REACH – REC
  1 files      59 downloads
Certificats Download

Résumé

ModelAirflow rate [m³/h]Automatic bypassPre/Post heatingERP 2016/2018
Mural P300T50-300yes -100%Yes/YesYes/Yes
Mural P400T50-400yes -100%Yes/YesYes/Yes
Mural PX 450 (FW & Top FW)50-450yes -70%Yes/YesYes/Yes
Mural PX 600 FW60-600yes -70%Yes/YesYes/Yes
Mural PX 800 FW100-800yes -70%Yes/YesYes/Yes
Mural PX 1200 FW100-1200yes -70%Yes/YesYes/Yes